0

bal.4 spike connect new

The movable ground spike luminaire bal.4 spike makes a real statement! It combines an elegant sphere of black high-gloss powder-coated aluminium and smoked glass with a fine ground spike, and creates warm light islands. Its perfect all-round light is scattered downwards by a diffuser.

Storefinder
Share

bal.4 spike deep black connect

bal.4 spike connect with 3 m supply cable and connect plug. For use in unpaved beds and greens.

The movable ground spike luminaire bal.4 spike makes a real statement! It combines an elegant sphere of black high-gloss powder-coated aluminium and smoked glass with a fine ground spike, and creates warm light islands. Its perfect all-round light is scattered downwards by a diffuser.

Impressions

Technical data

light technology light direction installation material protection class

230V Power LED

L70/50.000 h

dimmable via trailing edge dimmer

supply cable: 3 m luminaire (05RN8-F 3G1,0 mm²) incl. connect plug . cable can be shortened on request

assembly

for unpaved beds and greens

aluminium die-casting powder-coated

smoked glass

polycarbonate

IP65

bal.4 spike connect
dimensions in mm colour item no. system performance colour temperature
deep black RAL 9005 93057-BL-CO 4 W/155 lm
2700K

IP44.DE connect accessory

mains connection port
dimensions in mm item no. article description protection class
55100

5 m mains connection port . safety plug on connect socket . cable: H07RN-F 3G1,5 mm²

IP44

mains connection port with Swiss plug
dimensions in mm item no. article description protection class
55100-CH

5 m mains connection port . Swiss plug on connect socket . cable: H07RN-F 3G1,5 mm²

IP44

underground connection kit
dimensions in mm item no. article description protection class
55202

2 m connection port with connect socket, aquastop and open cable end . underground cable: H07RN8-F 3G1,5 mm² . earth distribution box incl. connection terminal + cast resin: installation: 7x cable entry point; connection terminal 5x 2,5 mm²

IP65

jack
dimensions in mm colour item no. article description protection class
anthracite RAL 7016 55090-AN

connecting pillar . incl. 2x safety sockets (EUR norm) . installation: connection terminal 5x 1,5 mm²; possibility of through wiring with Y-connector inside pillar . assembly: on site foundation or solid ground

IP54

cool brown 55090-CB

connecting pillar . incl. 2x safety sockets (EUR norm) . installation: connection terminal 5x 1,5 mm²; possibility of through wiring with Y-connector inside pillar . assembly: on site foundation or solid ground

IP54

deep black RAL 9005 55090-BL

connecting pillar . incl. 2x safety sockets (EUR norm) . installation: connection terminal 5x 1,5 mm²; possibility of through wiring with Y-connector inside pillar . assembly: on site foundation or solid ground

IP54

jack . BE+FR-norm
dimensions in mm colour item no. article description protection class
anthracite RAL 7016 55090-BEFR-AN

connecting pillar . incl. 2x safety sockets (Belgian/French norm) . installation: connection terminal 5x 1,5 mm;² possibility of through wiring with Y-connector inside pillar . assembly: on site foundation or solid ground

IP54

cool brown 55090-BEFR-CB

connecting pillar . incl. 2x safety sockets (Belgian/French norm) . installation: connection terminal 5x 1,5 mm;² possibility of through wiring with Y-connector inside pillar . assembly: on site foundation or solid ground

IP54

deep black RAL 9005 55090-BEFR-BL

connecting pillar . incl. 2x safety sockets (Belgian/French norm) . installation: connection terminal 5x 1,5 mm;² possibility of through wiring with Y-connector inside pillar . assembly: on site foundation or solid ground

IP54

jack . Swiss norm . protection class: IP55
dimensions in mm colour item no. article description protection class
anthracite RAL 7016 55090-CH-AN

contactdooszuil . incl. 2x geaard stopcontact (belgisch/frans norm) . installatie: aansluitklem 5x 1,5 mm² . doorgangsbedrading met Y-connector in de zuil mogelijk . montage: fundament ter plekke of verharde ondergrond

IP55

cool brown 55090-CH-CB

contactdooszuil . incl. 2x geaard stopcontact (belgisch/frans norm) . installatie: aansluitklem 5x 1,5 mm² . doorgangsbedrading met Y-connector in de zuil mogelijk . montage: fundament ter plekke of verharde ondergrond

IP55

deep black RAL 9005 55090-CH-BL

contactdooszuil . incl. 2x geaard stopcontact (belgisch/frans norm) . installatie: aansluitklem 5x 1,5 mm² . doorgangsbedrading met Y-connector in de zuil mogelijk . montage: fundament ter plekke of verharde ondergrond

IP55

earth connection port
dimensions in mm item no. article description protection class
55112

2 m connection port with connect socket, aquastop and open cable end . underground cable: H07RN8-F 3G1,5 mm²

IP65

extension cable [special lengths on request]
dimensions in mm item no. article description protection class
55105

5 m extension cable . connect plug on connect socket . cable: H07RN-F 3G1,5 mm²

IP65

55110

10 m extension cable . connect plug on connect socket . cable: H07RN-F 3G1,5 mm²

IP65

55102

2 m extension cable . connect plug on connect socket . cable: H07RN-F 3G1,5 mm²

IP65

Y-junction box
dimensions in mm item no. article description protection class
55122

Y-junction box . 1x connect plug, 2x connect socket

IP65

H-junction box
dimensions in mm item no. article description protection class
55123

H-junction box . 1x connect plug, 3x connect socket

IP65

sealing cap socket
dimensions in mm item no. article description
55192

sealing cap connect socket

controller
dimensions in mm item no. article description protection class
55400

compatibility: Casambi . in- and output voltage: 230V . max. output power: 100 W . transmission range: 60 m (free area)

IP65

Caring & Useful information

Our luminaires have been designed to do their job for many years. But we need a little help from you to make sure that they don't lose their looks as the years go by and that they will continue to bring you pleasure for a long time! Please clean your IP44.DE luminaires regularly. And please also remember that every material and every environment needs a different kind of care. To protect the threads of the luminaire bodies from galvanic corrosion, we recommend treating them with a grease-based paste that is suitable for outdoor use and that provides protection against corrosion after approximately 10 years. Please contact us if you require further information.

Application areas

It’s fabulous to have a house on the coast. But the salty air in coastal areas is a real challenge for aluminium. Our luminaires are therefore always designed to withstand salty air even in the long term. Furthermore, we now also offer some IP44.DE models with a coastal grade finish, which makes them extraordinarily corrosion resistant (please consult us for all other models). How do we know that? Because all models with a coastal-grade finish go through a real endurance test in a testing lab. In the salt spray test according to the standard DIN EN ISO 9227, they are sprayed with a saline solution at 35° Celsius in a test chamber for 2,000 hours. This proves that they really are ready for the coast.   

Condensation

High humidity levels or great fluctuations in temperature, climatic conditions which normally occur in spring and autumn, can cause condensation in the glass housing. This does not indicate a flaw in the product but is a natural consequence of the physical properties of water. The best way to deal with condensation is simply to leave the luminaire switched on for a while so that the condensation can dry out.

Caring for powder-coating

The luminaires have a powder-coated finish that offers high chemical and mechanical resistance. As with every surface, the colour shade of our powder-coated surfaces can also be changed when exposed to UV radiation (e.g. sunlight). Exposure to UV light can cause changes to the colour pigments embedded in the powder coating. A gentle, solvent-free household cleaner is all that's needed to care for the luminaire, which should then be rubbed off with a dry, soft cloth. Abrasive cleaners, steel wool, scouring pads, acids or alkali cleaning agents should not be used as these would damage the surface.